Cleaning Functions; Cleaning Parameters - WAGNER PXM Operating And Assembly Manual

Powder center
Table of Contents

Advertisement

VERSION 08/2015
OPERATING AND ASSEMBLY MANUAL
8.2.3

CLEANING FUNCTIONS

1
Injector
2
FP pump standard
3
FP pump intensive
4
US Sieve
5
RP hose
1 Perform impulse fl ushing of the injectors
– Interlock with guns in blowout positions (height and depth) for Profi Tech controllers
2 Clean the IP 5000 with internal cleaning program and/or preliminary clean US sieve
3 Perform pulse fl ushing of the IP 5000 via the blowout device
4 Perform main cleaning of the US sieve via the blowout device
5 Perform pulse cleaning of the peristaltic pump via blowout device
6 Activate suction gun (pinch valve is opened); only in conjunction with US sieve
8.2.4

CLEANING PARAMETERS

Operate the IP 5000 fresh powder pump in accordance with the IP 5000 operating
manual and "Clean fresh powder (FP)" machine parameter; see Chapter 7.7.3
Perform impulse fl ushing of the injectors; see "Clean injectors" machine parameter;
see Chapter 7.7.3
Perform impulse fl ushing of the ultrasonic sieve; see "Clean sieve" machine parameter;
see Chapter 7.7.3
Perform impulse fl ushing of the peristaltic pump; see "Clean reclaimed powder (RP)"
machine parameter; see Chapter 7.7.3
ORDER NUMBER DOC2350372
Worker
On
Off
On
Off
End
On
Off
On
Off
On
Off
6
Home page
Cleaning
Settings
Alarm
P_02706
PXM
72