First edition • First Printing
Machine Not Level Indicator Light
If the tilt alarm sounds when the
platform is raised, the Machine
Not Level indicator light will come
on and the drive function in one
or both directions will not operate.
Identify the condition of the boom
on the slope as shown below.
Follow the steps to lower the boom
before moving to a firm, level
surface. Do not rotate the boom
while lowering.
If the tilt alarm sounds with
the platform uphill:
1 Lower the primary
boom.
2 Lower the secondary
boom.
3 Retract the primary
boom.
If the tilt alarm sounds with
the platform downhill:
1 Retract the primary
boom.
2 Lower the secondary
boom.
3 Lower the primary
boom.
Part No. 1257143
Operating Instructions
Platform Overload Indicator Light
Light flashing indicates the
platform is overloaded and no
functions will operate. The LCD
screen on the platform control
panel will say PLATFORM IS
OVERLOADED.
Remove weight from the platform until the light
goes off.
If the platform controls LCD screen displays
OVERLOAD RECOVERY, the emergency lowering
system has been used while the platform was
overloaded. For information on how to reset this
message, please consult the appropriate Genie
Service Manual.
After Each Use
1 Select a safe parking location–firm level
surface, clear of obstruction and traffic.
2 Retract and lower the boom to the stowed
position.
3 Rotate the turntable so that the boom is
between the non-steer wheels.
4 Turn the key switch to the off position and
remove the key to secure from unauthorized
use.
5 Charge the batteries.