Replacing filter mats

NOTICE
Damage due to dust deposits
Dust can enter the interior of the cabinet during filter mat replacement due to the suction of the
running cabinet fans. Dust deposits can damage the device.
● Ensure that no dust enters the cabinet when replacing the filter mats.
1. Remove the screws for the louvered fan grid in the cabinet door.
2. Remove the filter mat.
3. If there is a slight amount of dirt, clean the filter mat at a suitable location. Depending on the
4. Insert the filter mat in the frame of the fan opening. In order that dirt is not drawn in, insert
5. Carefully place the louvered cover over the frame.
6. Retighten the cover screws.
9.4.6

Maintaining the fan

Injury caused by rotating fan
If the drive is equipped with a temperature-controlled fan, the fan can run on even if the power
section is switched off. You can be injured if you touch the fan.
● Wait until the fan has shut down and has come to a stop.
182
Figure 9-7
Example diagram: Replacing filter mats
degree of pollution, you can also clean the filter mats using a vacuum cleaner. If the filter mat
is damaged, or the frequency of alarms increases, dispose of the dirty filter mat in the correct
fashion. Use a new filter mat.
a clean mat in the same direction as it was installed before the cleaning.