Loading Dos Odi Workstation - SMC Networks Elite16 Manual

High performance 16-bit ethernet local area network adapters
Table of Contents

Advertisement

Loading DOS ODI
Workstation
<Escope> = Cancel
< Fl > = Help
<fllt><F10> = Exit
Select the configuration option that notches the setting on your netuork
board.
Netuork Board Driver:
SMC EtherCard PLUS v.X.XXEC (XXXXXX)
Second Softuare Configured Adapter
Third Softuare Configured Adapter
Fourth Softuare Configured Adapter
IRg=3. I/O Base=ZBeh. RAM at J>0Ba:0 for l&k
Highlight the configuration you uant. then press <Enter>
Figure 13. Available Adapter Options Menu
This section tells you how to set up
and install a workstation that uses
DOS ODI. The procedure for installing
this type of workstation is the same
whether you are loading NetWare 286
or 386.
To install DOS ODI workstations, do
the following:
1. Refer to Novell DOS ODI installation
menu.
2. Copy the NEICFG file to the direc-
tory where the ODI driver resides.
Note: There is no need to use the
NEICFG file if the SMC PLUS
adapter is an AT adapter con-
figured for the default settings;
Base I/O Address = 280
Interrupt IRQ = 3
RAM Base Address = DOOO.
51