Section 4 • Repair Procedures
GROUND CONTROLS
CE models with all software revisions:
22 Use the yellow platform down arrow to scroll to
return to the main menu.
Result:
RETURN TO MAIN MENU
diagnostic display window.
23 Press the lift function enable button.
Result:
SELECT OPTIONS
diagnostic display window.
24 Push in the red Emergency Stop button to the
off position at the ground controls.
4 - 58
is showing in the
is showing in the
GS-84 • GS-90
5-4
Level Sensor -
Models without Outriggers
The Electronic Control Module (ECM) is
programmed to deactivate the lift and drive
functions and activate an alarm when a signal is
received from the level sensor.
The tilt alarm sounds when the incline of the
chassis exceeds 2° to the side, or 3° to the front or
rear.
How to Install and Calibrate the
Level Sensor
Tip-over hazard. Failure to install
or calibrate the level sensor as
instructed could result in the
machine tipping over causing
death or serious injury. Do not
install or calibrate the level sensor
other than specified in this
procedure.
1 Perform this procedure with the machine on a
firm, level surface that is free of obstructions.
2 Remove the platform controls from the platform.
If you are not installing a new level sensor,
proceed to step 10.
3 Push in the red Emergency Stop button to the
off position at the platform controls.
4 Remove the ground control panel retaining
fasteners and open the panel.
5 Locate the level sensor behind the ground
control panel.
January 2013
Part No. 84793