Section 4 • Repair Procedures
GROUND CONTROLS
5-3

Software Configuration

The Electronic Control Module (ECM) contains
programming for all configurations of the GS-84
and GS-90. Machines can be adjusted to a
different configuration using the buttons at the
ground controls. To determine the software
revision level, see 7-2, How to Determine the
Revision Level.
ANSI and CSA models with
all software revisions:
1 Turn the key switch to ground controls and pull
out the red Emergency Stop buttons to the on
position at both platform and ground controls.
Result: The revision level of the ECM will
appear in the LED display window. Note the
result.
2 Push in the red Emergency Stop button to the
off position at the ground controls.
3 Press and hold both the blue platform up and
yellow platform down buttons. Pull out the red
Emergency Stop button to the on position at the
ground controls.
Result:
TUNE SPEEDS
display window.
a
a
diagnostic display
b
blue platform up button
c
lift function enable button
d
yellow platform down button
4 - 52
is showing in the diagnostic
Machine Option Definitions
Descent Delay: This option halts descent when the
down limit switch is activated. All controls must be
released for 4 to 6 seconds before descent is re-
enabled. Required for Europe.
Lift/Drive Cut Out: Lift and drive functions are
disabled when the down limit switch is activated
and the machine is on a slope exceeding the rating
on the serial plate. Activated for all machines.
Configuring this option to the ON/OFF position was
removed from ECM programming
after GS8407-41416 and GS9007-44277.
Motion Alarm: The motion alarm will sound when
activating a function.
Motion Beacons: The flashing beacons operate
only when activating a function.
Overload: This cuts out all functions when the
platform overload pressure switch is tripped. The
red Emergency Stop button must be cycled before
any function can be resumed. Required for Europe.
Sim Operation: When enabled, this allows some
machine functions to be activated simultaneously.
Required to be disabled for European models.
Beacons: When installed on the machine, the
flashing beacons operate continuously when the
key switch is turned to ground or platform controls
and both red Emergency Stop buttons are pulled
b
out to the on position.
c
Outriggers: When installed on the machine, the
outrigger option must be enabled.
d
Oscillating Axle: When installed on the machine,
the oscillating axle option must be enabled.
GS-84 • GS-90