Chapter 13 Profile Position Mode Objects; Target Position (Obj. 607Ah)]; [Target Position (Obj. 607Ah: 00H)]; Position Range Limit (Obj. 607Bh)] - Mitsubishi Electric Melservo-J5 Series User Manual

Hide thumbs Also See for Melservo-J5 Series:
Table of Contents

Advertisement

13
Profile Position Mode Objects
13.1

[Target position (Obj. 607Ah)]

[Target position (Obj. 607Ah: 00h)]

Data Type
Access
I32
RW
Description
Set the position command used in the cyclic synchronous velocity mode (csp).
13.2

[Position range limit (Obj. 607Bh)]

[Position range limit (Obj. 607Bh: 00h)]

Data Type
Access
U8
RO
Description
The total number of Sub Index (= 2) is returned.

[Min position range limit (Obj. 607Bh: 01h)]

Data Type
Access
I32
RW
Description
Set the range for limiting the command position.
[Position range limit (Obj. 607Bh)] cannot be written. If a value is written, this will result in witting error.

[Max position range limit (Obj. 607Bh: 02h)]

Data Type
Access
I32
RW
Description
Refer to the following object.
Page 84 [Min position range limit (Obj. 607Bh: 01h)]
13 Profile Position Mode Objects
84
13.1 [Target position (Obj. 607Ah)]
Mapping
Default
RXMAP
Mapping
Default
Impossible
2
Mapping
Default
RXMAP
Mapping
Default
RXMAP
Range
Units
80000000h to
pos units
7FFFFFFFh
Range
Units
2 (fixed)
Range
Units
80000000h to
pos units
7FFFFFFFh
Range
Units
pos units
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible

Advertisement

Table of Contents
loading

Table of Contents