Chapter 8 Manufacturer Specific Control Object; Drive Recorder Status (Obj. 2C02H)]; [Drive Recorder Status (Obj. 2C02H: 00H)]; Clear Drive Recorder History (Obj. 2C03H)] - Mitsubishi Electric Melservo-J5 Series User Manual

Hide thumbs Also See for Melservo-J5 Series:
Table of Contents

Advertisement

8
Manufacturer Specific Control Object
8.1

[Drive recorder status (Obj. 2C02h)]

[Drive recorder status (Obj. 2C02h: 00h)]

Data Type
Access
U16
RO
Description
The enabled/disabled status of the drive recorder is returned.
When the drive recorder does not operate or when one-shot sampling ends in manual setting mode, this object returns "0"
(disabled status).
When the drive recorder function is operating, this object returns "1" (enabled status).
0: Disabled status
1: Enabled status
8.2

[Clear drive recorder history (Obj. 2C03h)]

[Clear drive recorder history (Obj. 2C03h: 00h)]

Data Type
Access
U16
RW
Description
Writing "1EA5h", cycling the power, or performing a software reset clears the data in the drive recorder history.
When the object is read, "0000h" is returned.
8.3

[Power ON cumulative time (Obj. 2C18h)]

[Power ON cumulative time (Obj. 2C18h: 00h)]

Data Type
Access
U32
RO
Description
The cumulative energization time of the servo amplifier is returned.
8.4

[Inrush relay ON/OFF number (Obj. 2C19h)]

[Inrush relay ON/OFF number (Obj. 2C19h: 00h)]

Data Type
Access
U32
RO
Description
The number of on/off times of the inrush relay of the servo amplifier is returned.
8 Manufacturer Specific Control Object
50
8.1 [Drive recorder status (Obj. 2C02h)]
Mapping
Default
Impossible
0
Mapping
Default
Impossible
0000h
Mapping
Default
Impossible
Mapping
Default
Impossible
Range
Units
0 to 1
Range
Units
0000h to FFFFh
Range
Units
00000000h to
hour
FFFFFFFFh
Range
Units
00000000h to
number of times
FFFFFFFFh
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible

Advertisement