Samsung DVM PLUS III Technical Data Book page 544

Hide thumbs Also See for DVM PLUS III:
Table of Contents

Advertisement

05-1_control systems(002~045)
Control Systems
1
Individual control system
1
1-3. Wired remote controller
1) MWR-TH01
(3) Description of buttons and functions
No.
1
Defrost operation icon
2
Operation mode icon
3
Central control display
4
Set temperature display
5
Fan speed display
6
Louver swing icon
7
Filter replacement alarm display
8
Error indicator
9
On timer display
10
Off timer display
11
Operation On/Off button
12
Operation LED
13
Fan speed button
14
Air flow setting button
15
Filter replacement alarm reset button Press this button to clear the filter replacement alarm on the display.
16
Operation mode setting button
Temperature
17
setting button
18
Timer button
Operation timer set/
19
cancel button
20
Error checking button
V-12
3/15/08 4:09
Page 12
8
9
10
17
18
19
20
Name
Displayed when Defrost operation is started.
Indicates the current operation mode.
Indicates that the remote controller prohibition option is set.
(Only upper controller, such as the Centralized controller, can control indoor unit).
Indicates the set temperature.
Indicates the fan speed setting. ( Low, Medium, High, or Auto)
Indicates that the louver is in swing mode.
Indicates that filter replacement time has passed.
Indicates that an error occurred in indoor units, outdoor unit, or wired remote controller.
Indicates that On timer setting is on.
Indicates that Off timer setting is on.
Press this button to turn on all indoor units connected to the wired remote controller.
Press again to turn off all connected indoor units.
Turned on if indoor unit which is connected to the wired remote controller operates ON.
Press the button to select one fan speed ( Auto, Low, Medium, or High.)
Press this button to adjust the air flow direction.
Press this button to select operation mode in the following order: Auto-Cool-Dry-Fan-Heat.
Press Up / Down buttons to set the temperature.
1) When an indoor unit is turned Off: When the button is pressed, it enters the operation
OFF timer mode to decrease time by 30 minutes.
2) When an indoor unit is turned On: When the button is pressed, it enters the operation
ON timer mode to increase time by 30 minutes.
When there is no operation timer setting: no change.
When an operation timer is under way: confirm the reservation.
When there is an operation timer setting: cancel the reservation.
When
icon appears, press this button to check the error code that has occurred.
1
2
3
16
Description
4
5
6
7
11
12
13
14
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvm plus iii hrMini dvm

Table of Contents