Model
Power Supply
1)
Mode*
Performance
Capacity
Cooling*
Heating*
Condensate (with High fan speed)
Power
Input
Running Current
Sound Level
Sound Pressure (High/Low)*
Fan
Type
Motor
Model
Type
Output
Cooling (High)
Airflow Rate
Heating (High)
Refrigerant
Type
Control Method
Temperature Control
Safety Devices
Option Code
Liquid (Flare)
Piping
Connections
Gas (Flare)
Drain
Weight
Net Weight
Shipping Weight
Dimensions
Net Dimensions (W x H x D)
Shipping Dimensions (W x H x D)
Auto Restart
Functions
Auto Swing
Group/Individual Control
External Contact Control
Trouble Shooting by LED
Standard
Installation Manual
Accessories
Operation Manual
Pattern Sheet for Installation
Flexible Drain Hose
Filter / Safety Grille
Wireless Remote Controller
Wireless Remote Controller
Optional
Accessories
Simplified
Wired Remote
Controller
Standard
Premium
External Contact Interface Module
EEV Kits
*1) Mode
- HP : Heat Pump, HR : Heat Recovery
*2) Nominal cooling capacities are based on;
- Indoor temperature : 27°C DB, 19°C WB
- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m
*3) Nominal heating capacities are based on;
- Indoor temperature : 20°C DB, 15°C WB
- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m
*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
*5) Specifications may be subject to change without prior notice for product improvement.
3/14/08 22:38
Page 133
AVXWVH022E✴
ø/V/Hz
1/220~240/50
HP / HR
2)
kW
2.2
7,500
Btu/h
3)
kW
2.5
Btu/h
8,500
Liters/h
1.12
W
30
0.13
A
4)
dB(A)
31
*5)
/ 21
*5)
Crossflow Fan
-
-
YDK-016S41408-01
-
Feedback SSR
W
23
*5)
m
3
/min
8.8
*5)
3
6.1
*5)
m
/min
-
R410A
EEV (Optional)
-
-
Micom&Thermistors
-
Fuse
-
004602-1120E7-200000-300000
ø, mm
6.35
12.70
ø, mm
ø, mm
ID 18 hose
kg
8.5
kg
11.5
mm
825x285x189
mm
900x349x252
-
O
O
-
-
O
-
O
-
O
-
O
O
-
-
X
O
-
-
Filter (Washable)
-
ARH-1364
-
MR-BH01
-
MWR-SH00
MWR-TH01
-
-
MWR-WS00
MIM-B14
-
MXD, MEV Series
AVXWVH028E✴
AVXWVH036E✴
1/220~240/50
1/220~240/50
HP / HR
HP / HR
2.8
3.6
9,500
12,200
3.2
4.0
10,900
13,600
1.44
1.91
30
35
0.18
0.19
31 / 21
35 / 21
Crossflow Fan
Crossflow Fan
YDK-016S41408-01
YDK-016S41408-01
Feedback SSR
Feedback SSR
23
*5)
23
*5)
7.0
*5)
8.2
*5)
7.3
*5)
8.9
*5)
R410A
R410A
EEV (Optional)
EEV (Optional)
Micom&Thermistors
Micom&Thermistors
Fuse
Fuse
004602-1320E7-200000-300000
007602-15221A-200000-300000
6.35
6.35
12.70
12.70
ID 18 hose
ID 18 hose
8.5
8.5
11.5
11.5
825x285x189
825x285x189
900x349x252
900x349x252
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
X
O
O
Filter (Washable)
Filter (Washable)
ARH-1364
ARH-1364
MR-BH01
MR-BH01
MWR-SH00
MWR-SH00
MWR-TH01
MWR-TH01
MWR-WS00
MWR-WS00
MIM-B14
MIM-B14
MXD, MEV Series
MXD, MEV Series
AVXWVH056E✴
AVXWVH071E✴
1/220~240/50
1/220~240/50
HP / HR
HP / HR
5.6
6.8
19,100
23,200
6.3
7.0
21,400
23,800
3.03
3.51
50
50
0.30
0.30
40 / 30
41 / 30
Crossflow Fan
Crossflow Fan
YDK-045S42213-02
YDK-045S42213-02
Feedback SSR
Feedback SSR
42
*5)
42
*5)
13.3
*5)
13.3
*5)
14.0
*5)
14.0
*5)
R410A
R410A
EEV (Optional)
EEV (Optional)
Micom&Thermistors
Micom&Thermistors
Fuse
Fuse
005606-1A225E-200000-300000
005606-1C2371-200000-300000
6.35
9.52
12.70
15.88
ID 18 hose
ID 18 hose
12.0
12.0
15.0
15.0
1,065x298x218
1,065x298x218
1,137x377x299
1,137x377x299
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
X
O
O
Filter (Washable)
Filter (Washable)
ARH-1364
ARH-1364
MR-BH01
MR-BH01
MWR-SH00
MWR-SH00
MWR-TH01
MWR-TH01
MWR-WS00
MWR-WS00
MIM-B14
MIM-B14
MXD, MEV Series
MXD, MEV Series
II-133