6.6.2 Compact

This procedure is valid for Compact machines
wich have the control panel in front of the op-
erator.

Dismantling of PTO engagement wire

1. Release and unhook the upper and lower
adjustment sleeves.
2. Release the wire from the tension spring at
the belt tensioner.
3. Release the wire Z nipple from the lever
under the seat.
4. Remove the wire from the machine.
Do not forget to cut off the cable holder that
holds the cables and wires in the articula-
tion point.
Notice how the wire is routed, since it sim-
plifies fitting if the new wire is routed in the
same way as the old one.
Assembly of PTO engagement wire
Assemble in the reverse order.
It is often easier to fit the wire from underneath,
since the Z nipple is easier to guide correctly than
the spring attachment in the bottom end of the
wire.
Follow-up work
Warning!
The PTO brake is part of the ma-
chine's safety system. It is therefore
especially important that it is
checked and adjusted correctly.
Adjust the wire and the PTO brake.
See "Adjustment of PTO wire and brake" at
page 18.