Indicator Led - Denso GT20Q-SB User Manual

2d code handy scanner
Table of Contents

Advertisement

8.2 Indicator LED

The indicator LED illuminates or flashes in blue, green, red or orange as described below.
The indicator LED illuminates in blue when:
- the code has scanned successfully,
- a split QR Code is scanned,
- the scanned code matches the master data in "data verification mode," or
- the master data has been registered successfully in "data verification mode".
The indicator LED illuminates in green when:
- a transfer has been commenced with the data retransfer function,
- a code has been scanned successfully while the scanning code switching function or the barcode reader mode switching
function is enabled,
- a transfer has been commenced with the specific character transfer function,
- the scanner is in master data registration standby state in the data verification mode, or
- the barcode reader mode is temporarily released.
The indicator LED illuminates in red when:
- the trigger switch is pulled when the trigger switch control is deactivated, or
®
- Bluetooth
communication has been disconnected.
The indicator LED flashes in red when:
- the scanner has received an abnormal control command,
- the scanner has failed to edit read data,
- the master data has not been registered successfully in "data verification mode (n-point),"
- the code scanned in "data verification mode" does not match the master data,
- a digit number error has occurred during master code registration in "data verification mode,"
- data stored in Split mode exceeds 8KB,
- the scanner has failed to save the set parameter values specified with the configuration software, QR-coded parameter menu,
or control commands,
- a code other than a parameter setting code is scanned during parameter setting via the QR-coded parameter menu,
- a communication error or communication timeout occurs while setting parameters with the configuration software,
- a run-time error has occurred in ADF script,
- the trigger switch is pulled while Bluetooth
- the trigger switch is pulled while End operation has been set.
®
communication has been disconnected in the operation-enabled state, or