Denso GT20Q-SB User Manual page 135

2d code handy scanner
Table of Contents

Advertisement

Scan code, Check digit, Minimum digits and Maximum digits must be set as shown on the table below.
Scan code Readable codes
A
UPC-A, UPC-E, EAN-8, EAN-13
UPC-A, UPC-E, EAN-8, EAN-13
E
UPC/EAN with Add-on
H
Standard 2 of 5 (STF)
I
Interleaved 2 of 5 (ITF)
N
Codabar (NW-7)
M
Code 39
L
Code 93
K
Code 128, GS1-128
GS1 DataBar Omnidirectional,
GS1 DataBar Stacked,
R
GS1 DataBar Truncated,
GS1 DataBar Stacked Omnidirectional
Specify Scan code and Check digit by the alphabet symbol, minimum and maximum number of digits by the alphabet
symbol followed by one or two digits of numeric number(s).
Settable range is from the minimum number of digits to the maximum number of digits. The default value shown on the
table above is set if the minimum and maximum number of digits are not set.
Note 1: An error occurs if the symbol A and E are specified at the same time.
Note 2: The minimum number of digits is three for multiple reading, one for simgle reading.
Note 3: The minimum number of digits is four for multiple reading, two for simgle reading.
Note 4: The minimum number of digits can be set to one, and will be set to the value shown on the table above if not set.
Check digit
-
-
H
I
N
M
-
-
-
122
Minimum
Maximum
number of
number of
digits
digits
-
-
-
-
(Note 2)
H3
H99
(Note 3)
I4
I99
(Note 4)
N4
N99
M1
M99
L1
L99
K1
K99
R1
R99