11.19 Parameters that Change from the Default Settings with E3-01 [Motor 2 Control Mode Selection]

11.19 Parameters that Change from the Default Settings with
E3-01 [Motor 2 Control Mode Selection]
The values for the parameters in these tables depend on the values for parameter E3-01. When you change the
setting for E3-01, the default settings will change.
No.
Name
C3-21
Motor 2 Slip Compensation Gain
C3-22
Motor 2 Slip Comp Delay Time
Motor 2 Maximum Output
E3-04
Frequency
E3-05
Motor 2 Maximum Output Voltage
E3-06
Motor 2 Base Frequency
E3-07
Motor 2 Mid Point A Frequency
E3-08
Motor 2 Mid Point A Voltage
Motor 2 Minimum Output
E3-09
Frequency
E3-10
Motor 2 Minimum Output Voltage
E3-11
Motor 2 Mid Point B Frequency
E3-12
Motor 2 Mid Point B Voltage
E3-13
Motor 2 Base Voltage
*1
This is the value for 200 V class drives. Double the value for 400 V class drives.
YASKAWA SIEPC71061753A GA500 Technical Manual
Range
Unit
0.0 - 2.50
0.1
0 - 10000
1 ms
40.0 - 590.0
0.1 Hz
0.0 - 255.0
0.1 V
*1
0.0 - 590.0
0.1 Hz
0.0 - 590.0
0.1 Hz
0.0 - 255.0
0.1 V
*1
0.0 - 590.0
0.1 Hz
0.0 - 255.0
0.1 V
*1
0.0 - 590.0
Determined by o1-04
0.0 - 255.0
0.1 V
*1
0.0 - 255.0
0.1 V
*1
Motor 2 Control Method (setting value of E3-01)
V/f
(0)
0.0
2000
60.0
200.0
60.0
3.0
15.0
1.5
9.0
0.0
0.0
0.0
OLV
(2)
1.0
200
60.0
200.0
60.0
3.0
11.0
0.5
2.0
0.0
0.0
0.0
11