6.3  Standard Platform Connections
Standard Equipment
(equivalent
Analog I/O
Connector type
HDB15M
The 0-10 V analog inputs have an input impedance of about 35 kΩ.
l
The 0-30 V analog inputs have an input impedance of about 110 kΩ.
l
The analog outputs have an output impedance of about 200 Ω.
l
92
37
VBAT_IO_OUT4
Wiring Terminal Block
40
VBAT_IO_OUT1
21
OUTPUT_1
22
OUTPUT_2
23
OUTPUT_3
24
OUTPUT_4
circuit)
25
OUTPUT_5
36
OUTPUT_16
41
GND
44
GND
Figure 6-7. Typical Digital Output Wiring Example
Pin No.
Designation
1
ANALOG_IN1
2
ANALOG_IN2
3
ANALOG_IN3
4
ANALOG_IN4
5
ANALOG_IN5
6
ANALOG_IN6
7
ANALOG_IN7
8
ANALOG_IN8
9
ANALOG_OUT1 0-20 V Range
10
ANALOG_OUT2 0-20 V Range
11
ANALOG_OUT3 0-20 V Range
12
ANALOG_OUT4 0-20 V Range
13, 14, 15 GND
LD Platform Cart Transporter User's Guide
User-Supplied Equipment
Typical User Loads
Load
Load
Load
Notes
0-10 V Range
0-10 V Range
0-10 V Range
0-10 V Range
0-30 V Range
0-30 V Range
0-30 V Range
0-30 V Range