3. Replacement and Adjustment

Idle Registration Roller Panel

3
1. Open the upper unit.
2. Side covers. (See p.112 "Side Covers".)
3. Toner hopper cover (See p.115 "Toner Hopper Cover".)
4. Disconnect the connector and ground wire [A] ( x 1,  x 1).
5. Idle registration roller panel [B] ( x 2)
• Remove the two rear screws [C] first and let the panel come down. Use a very short screwdriver
to remove the rear screws.
• Disconnect the panel from the stud screw on the right side first [D], then the left side. Do not
remove the stud screws.
Reinstallation
• Make sure that the mylar [C] is on the front edge of the exposure glass.