Folder Unit Jams - Ricoh Neptune-P1 Service Manual

Table of Contents

Advertisement

4. Troubleshooting
Plotter Lag Jams
Code
053
Roll 1 Feed Lag
054
Roll 2 Feed Lag
055
Paper Cassette Lag
058
Roll Feeder Exit Jam
063
Registration Jam
4
066
Fusing Exit Jam
084
Bypass Jam

Folder Unit Jams

Folder Unit Standby Jams
Code
100
Initial Jam: Folder Entrance
Initial Jam: Relay Sensor
Initial Jam: Fan Folder Entrance
Initial Jam: Fan Folding (Front)
Initial Jam: Fan Folding (Rear)
Initial Jam: Folder Unit Exit
Initial Jam: Straight-Through Exit
Initial Jam: Manual Feeder Entrance
Initial Jam: Folder Unit Entrance
(from Manual Feed unit)
Initial Jam: Bypass Entrance
Initial Jam: Bypass Entrance
214
Location
Display
Location
A2
Roll paper failed to feed
A2
Roll paper failed to feed
A1
Cut sheets failed to feed
A2
RF exit sensor failed to go OFF
B
Paper registration sensor failed to go OFF.
C
Fusing exit sensor failed to go OFF.
B
Paper set sensor failed to go OFF.
Display
N1
Folder entrance sensor
N5
Relay sensor 1
N7
Fan folder entrance sensor
N7
Fan fold LED (F1), fan fold sensor (F2) pair
N7
Fan fold LED (R1), fan fold sensor (R2) pair
N7
Folder unit exit sensor
N3
Straight-Through Sensor
V1
Bypass Entrance Sensor
V2
Bypass Relay Sensor
V1
Paper Width Sensor (880)
V1
Paper Width Sensor (841)
Comment
Comment

Advertisement

Table of Contents
loading

Table of Contents