Configuring Switch-Based Authentication
How to Configure Switch-Based Authentication

Configuring RADIUS Authorization for User Privileged Access and Network Services

Command
1.
configure terminal
2.
aaa authorization network radius
3.
aaa authorization exec radius
4.
end

Starting RADIUS Accounting

Command
1.
configure terminal
2.
aaa accounting network start-stop
radius
3.
aaa accounting exec start-stop radius
4.
end

Configuring Settings for All RADIUS Servers

Command
1.
configure terminal
2.
radius-server key string
3.
radius-server retransmit retries
4.
radius-server timeout seconds
Purpose
Enters global configuration mode.
Configures the switch for user RADIUS authorization for all
network-related service requests.
Configures the switch for user RADIUS authorization if the user has
privileged EXEC access.
The exec keyword might return user profile information (such as
autocommand information).
Returns to privileged EXEC mode.
Purpose
Enters global configuration mode.
Enables RADIUS accounting for all network-related service requests.
Enables RADIUS accounting to send a start-record accounting notice at
the beginning of a privileged EXEC process and a stop-record at the
end.
Returns to privileged EXEC mode.
Purpose
Enters global configuration mode.
Specifies the shared secret text string used between the switch and all
RADIUS servers.
Note:
The key is a text string that must match the encryption key used on
the RADIUS server. Leading spaces are ignored, but spaces within and at
the end of the key are used. If you use spaces in your key, do not enclose
the key in quotation marks unless the quotation marks are part of the key.
Specifies the number of times the switch sends each RADIUS request to
the server before giving up. The default is 3; the range 1 to 1000.
Specifies the number of seconds a switch waits for a reply to a RADIUS
request before resending the request. The default is 5 seconds; the range
is 1 to 1000.