Configuring Embedded Event Manager
Related Documents
Switch(config-applet)# event snmp oid 1.3.6.1.4.1.9.9.48.1.1.1.6.1 get-type exact entry-op lt entry-val
5120000 poll-interval 10
These examples show actions that are taken in response to an EEM event:
Switch(config-applet)# action 1.0 syslog priority critical msg "Memory exhausted; current available
memory is $_snmp_oid_val bytes"
Switch (config-applet)# action 2.0 force-switchover
This example shows the sample output for the show event manager environment command:
Switch# show event manager environment all
No.
Name
1
_cron_entry
2
_show_cmd
3
_syslog_pattern
4
_config_cmd1
5
_config_cmd2
This example shows a CRON timer environment variable, which is assigned by the software, to be set to every second
minute, every hour of every day:
Switch (config)# event manager environment_cron_entry 0-59/2 0-23/1 * * 0-6
This example shows the sample EEM policy named tm_cli_cmd.tcl registered as a system policy. The system policies
are part of the Cisco IOS image. User-defined TCL scripts must first be copied to flash memory.
Switch (config)# event manager policy tm_cli_cmd.tcl type system
Related Documents
Cisco IOS Master Command List, All Releases
Cisco IOS Embedded Event Manager Command Reference
Cisco IOS 15.2M&T Command References, Network Management
Embedded Event Manager Configuration Guide, Cisco IOS Release 15M&T
Value
0-59/2 0-23/1 * * 0-6
show ver
.*UPDOWN.*Ethernet1/0.*
interface Ethernet1/0
no shut