Configuring Embedded Event Manager
Configuring Embedded Event Manager
Command
1.
configure terminal
2.
event manager applet
applet-name
3.
event snmp oid oid-value
get-type {exact | next} entry-op
{gt | ge | eq | ne | lt | le} entry-val
entry-val [exit-comb {or |and}]
[exit-op {gt | ge | eq | ne | lt | le}]
[exit-val exit-val] [exit-time
exit-time-val] poll-interval
poll-int-val
4.
action label syslog [priority
priority-level] msg msg-text
5.
end
EXAMPLE
The following example shows how to configure an EEM applet that runs when there is an exact match on the value of a
specified SNMP object ID that represents the amount of current process memory.
Switch(config-applet)# event snmp oid 1.3.6.1.4.1.9.9.48.1.1.1.6.1 get-type exact entry-op lt entry-val
5120000 poll-interval 10
These examples show actions that are taken in response to an EEM event:
Switch(config-applet)# action 1.0 syslog priority critical msg "Memory exhausted; current available
memory is $_snmp_oid_val bytes"
Switch (config-applet)# action 2.0 force-switchover

Registering and Defining an Embedded Event Manager TCL Script

BEFORE YOU BEGIN
Review the
Information About Embedded Event Manager, page
Purpose
Enter global configuration mode.
Register the applet with EEM and enter applet configuration
mode.
Specify the event criteria that causes the EEM applet to run.
(Optional) Exit criteria. If exit criteria are not specified, event
monitoring is re-enabled immediately.
Specify the action when an EEM applet is triggered. Repeat this
action to add other CLI commands to the applet.
(Optional) The priority keyword specifies the priority level of
the syslog messages. If selected, you need to define the
priority-level argument.
For msg-text, the argument can be character text, an
environment variable, or a combination of the two.
Exit applet configuration mode and return to privileged EXEC
.
mode
789.