Maintenance
Check the Hydraulic Oil Level
Maintaining the hydraulic oil at the proper level is
essential to machine operation. Improper hydraulic
oil levels can damage hydraulic components. Daily
checks allow the inspector to identify changes in oil
level that might indicate the presence of hydraulic
system problems.
1
Be sure that the boom is in the stowed
position.
2
Visually inspect the sight gauge located on the
side of the hydraulic oil tank.
Result: The hydraulic oil level should be within
the top 2 inches / 5 cm of the sight gauge.
3
Add oil as needed. Do not overfill.
Hydraulic oil specifications
Hydraulic oil type
62
Chevron Rando HD equivalent
Check the Engine Coolant Level –
Liquid Cooled Models
Maintaining the engine coolant at the proper level
is essential to engine service life. Improper coolant
level will affect the engine's cooling capability and
damage engine components. Daily checks will
allow the inspector to identify changes in coolant
level that might indicate cooling system problems.
Burn hazard. Beware of hot engine parts and
coolant. Contact with hot engine parts and/or
coolant may cause severe burns.
Burn hazard. Do not remove the radiator cap if
the engine has been running. Contact with
pressurized coolant may cause severe burns.
Allow engine to cool before removing the
radiator cap.
1
Check the fluid level in the coolant recovery
tank. Add fluid as needed.
Result: The fluid level should be at the
mark on the tank or visible in the sight gauge.
S-60X
Second Edition • First Printing
FULL
Part No. 1261735

Hide quick links: