Genie S-60X Operator's Manual page 48

Hide thumbs Also See for S-60X:
Table of Contents

Advertisement

Operator's Manual
Operating Instructions
Emergency Stop
Push in the red Emergency Stop button to the off
position at the ground controls or the platform
controls to stop all machine functions and turn the
engine off.
Repair any function that operates when either red
Emergency Stop button is pushed in.
Selecting and operating the ground controls will
override the platform red Emergency Stop button.
Emergency Power
Use emergency power if the primary power source
(engine) fails.
1
Turn the key switch to ground or platform
control.
2
Pull out the red Emergency Stop button to the
on position.
3
Press down the foot switch when using the
controls from the platform.
4
Simultaneously hold the emergency
power switch to either side and
activate the desired function.
The drive and steer functions will not operate with
emergency power.
46
Operation from Ground
1
Turn the key switch to ground control.
2
Pull out the red Emergency Stop button to the
on position.
3
Gasoline/LPG models: Choose fuel by moving
the fuel select switch to the desired position.
4
Start the engine.
To Position Platform
1
Move and hold the
platform capacity
select/function enable
switch. See Platform
Capacity Selection
section.
2
Move the appropriate toggle switch according
to the markings on the control panel.
Drive and steer functions are not available from the
ground controls.
S-60X
Second Edition • First Printing
Part No. 1261735

Hide quick links:

Advertisement

Table of Contents
loading