Test the Machine Functions and the
Platform Capacity Selection
Note: Perform this test with less than 500 lbs /
227 kg in the platform.
23 Pull out the red Emergency Stop button to the
on position.
Result: Both capacity indicator lights should
flash.
24 Press down the foot switch. Test each
machine function.
Result: The boom raise and extend functions
should not operate.
25 Move the platform capacity select switch to the
left to select 1000 lbs / 454 kg capacity.
26 First, fully raise and then fully extend the boom
to full height. Lower the boom.
Result: The boom should stop part way down
and the 500 lbs / 227 kg capacity indicator light
should flash.
27 Retract the boom to continue and then fully
retract and lower the boom.
Part No. 1261735
Test the Foot Switch
28 Push in the platform red Emergency Stop
button to the off position.
29 Pull out the red Emergency Stop button to the
on position and do not start the engine.
30 Press down the foot switch and attempt to start
the engine by moving the start toggle switch to
either side.
Result: The engine should not start.
31 Do not press down the foot switch and restart
the engine.
Result: The engine should start.
32 Do not press down the foot switch and test
each machine function.
Result: No functions should operate.