optional wall thermostat

A wall thermostat may be installed if desired.
Connect the wires as per the wiring diagrams.
Note: Preferable if the thermostat is installed
on an interior wall.
CAUTION
Do not connect the wall
thermostat wires
to the 120V wires.
manual operation
(no remote)
To override the remote - open the front lower
door and locate the reset button. Remove
the lower access panel (see instructions in
this manual). Press the red button on IFC
until it beeps 3 times and the amber light
illuminates,within 10 seconds press and hold
the red button again until a beep is heard.
After overriding the remote - the ON/OFF switch
located on the lower left, inside the lower front
door.
tooltip
tooltip

final check

Before leaving this unit with the customer, the installer
must ensure that the appliance is firing correctly.
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label) at 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15 min. to stabilize.
3. Check for proper draft.
CAUTION
Any alteration to the product that causes sooting
or carboning that results in damage to the exterior
facia is not the responsibility of the manufacturer.

back up battery

In the event of a power outage the unit may be
operated by a back up battery system.
1. Open lower door of unit.
2. Install 4 AA batteries into battery pack.
3. Attach battery pack to left wall on unit near the
reset switch, ON/OFF switch with velcro.