general vent
maintenance
Conduct an inspection of the venting system semi-
annually. Recommended areas to inspect as follows:
1. Check the Venting System for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.
2. Remove the Cap, and shine a flashlight down
the Vent. Remove any bird nests, or other foreign
material.
3. Check for evidences of excessive condensa-
tion, such as water droplets forming in the inner
liner, and subsequently dripping out the joints,
Continuous condensation can cause corrosion
of caps, pipe, and fittings. It may be caused
by having excessive lateral runs, too many
elbows, and exterior portions of the system
being exposed to cold weather.
4. Inspect joints, to verify that no pipe sections or
fittings have been disturbed, and consequently
loosened. Also check mechanical supports such
as Wall Straps, or plumbers' tape for rigidity.
5. Verify proper operation after servicing.

log replacement

The unit should never be used with broken logs. Turn
off the gas valve and allow the unit to cool before
opening door to carefully remove the logs. The pilot
light generates enough heat to burn someone. If
for any reason a log should need replacement, you
must use the proper replacement log. The position
of these logs must be as shown in the diagram
under Log Installation.
Note: Improper positioning of logs may
create carbon build-up and will alter
tooltip
the unit's performance which is not
covered under warranty.
glass
replacement
Your stove is supplied with high temperature, 5
mm Neoceram ceramic glass that will withstand
the highest heat that your unit will produce. In the
event that you break your glass by impact, purchase
your replacement door from an authorized Regency
dealer only, and follow our step-by-step instructions
for replacement.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all
product warranties.
* Care must be taken to avoid breakage of
the glass.
* Do not strike or abuse the glass.
* Do not operate this fireplace without the
glass front or with a cracked or broken
glass front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panels should be
done by a licensed or qualified service per
son.
WARNING: Do not operate appliance
with the glass front removed, cracked, or
broken. Replacement of the glass should
be done by a licensed or qualified service
person.
1. Turn off unit and allow to cool to room temperature.
2. Open front glass door (see details in this manual).
3. Remove 4 bolts and brackets to release front glass.
owner's information
4. Replace glass and gasket-- secure with same
brackets and bolts removed in Step 3
®
Front door glass brackets
5. Side glass panels can be replaced in the same
manner as the front glass - but there are only 2
brackets securing each piece of side glass as
shown below.
Side glass brackets