Copy Of The Lighting Plate Instructions - Regency Contura RC500E Owners & Installation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

copy of the lighting plate instructions

FOR YOUR SAFETY READ BEFORE LIGHTING
This appliance must be installed in accordance with local codes, if any;
if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or
Natural Gas and Propane Installation Codes, CSA B149.1.
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life. Improper installation, adjustment,
alteration, service or maintenance can cause injury or property damage. Refer to the owner's
information manual provided with this appliance. For assistance or additional information
consult a qualified installer, service agency or gas supplier.
AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice
risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou
la mort.
Tout défaut d'installation, d'ajustement, de modification, de service ou d'entretien peut provo-
quer des blessures ou des dommages matériels. Reportez-vous au manuel du propriétaire de
l'information fournie avec cet appareil. Pour obtenir de l'aide ou des informations supplémen-
taires consulter un installateur qualifié, une agence de service ou fournisseur de gaz.
A) This appliance is equipped with an ignition device which automatically lights the pilot.
Do not try to light the pilot by hand.
B) BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch, do not use any phone in your building.
- Immediately call your gas supplier from a neighbours phone. Follow the gas supplier's instructions.
- If you cannot reach your gas supplier, call the fire department.
C) Do not use this appliance if any part has been under water. Immediately call a qualified service
technician to inspect the appliance and replace any part of the control system and any
gas control which has been underwater.
D) If the appliance will not operate, follow the instructions, "To Turn Off Gas To Appliance" and call your service
technician or gas supplier.
A) Cet appareil est muni d'un dispositif d'allumage qui allume automatiquement la veilleuse.
Ne tentez pas d'allumer la veilleuse manuellement.
B) AVANT DE FAIRE FONCTIONNER, reniflez tout autour de l'appareil pour déceler une odeur
de gaz. Reniflez près du plancher, car certains gaz sont plus lourds que l'air et peuvent
s'accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne tentez pas d'allumer d'appareil
• Ne touchez à aucun interrupteur; ne vous servez pas des téléphones se trouvant dans le
bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur, appelez le service incendie.
C) N'utilisez pas cet appareil s'il a été plongé dans l'eau, même partiellement. Faites inspecter l'appareil par un tech-
nicien qualifié et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l'eau.
D) Si l'appareil ne se met pas en marche, suivez les instructions intitulées «Comment couper l'admission de gaz de
l'appareil» et appelez un technicien qualifié ou le fournisseur de gaz.
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface
temperatures keep children, clothing and furniture, gasoline and other liquids having flammable
vapors away. Keep burner and control compartment clean. See installation and operating
instructions accompanying appliance.
1) Ensure the Main switch is in the ON position and/or the battery holder switch is in the Remote position.
2) Press and release the ON/OFF button on the remote handheld transmitter. An audible beep should be
heard from the receiver.
3) After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.
4) The unit will turn on.
Note: The first attempt to ignition will last approximately 60 seconds. If there is no flame ignition (rectifica-
tion) the board will stop sparking for approximately 35 seconds. After this wait time, the board will start a
second try for ignition by sparking for approximately 60 seconds. If there is still no positive ignition after the
second attempt the board will go into lock out.
The system will need to be reset as follows (after going into lock out mode):
a) Wait 5 minutes - turn the system off by pressing the ON/OFF button on the remote.
b) After approximately 2 seconds press the ON/OFF button again.
c) Unit will repeat step 2.
1) S'assurer que l'interrupteur principal est sur ON et/ou que l'interrupteur du support de piles est en posi-
tion télécommande.
2) Appuyer sur la touche ON/OFF de la télécommande et relâcher. Un bip se fera entendre depuis le récep-
teur.
3) Après environ 4 secondes, le système d'allumage produira des étincelles pendant 60 secondes pour al-
lumer le brûleur principal.
4) L'appareil s'allume.
Remarque : Au premier allumage, le système tente d'allumer les flammes pendant 60 secondes. Si l'essai
est infructueux, le système fait une pause de 35 secondes. C'est ce qu'on appelle l'étape de rectification.
Ce délai écoulé, le système tente à nouveau d'allumer les flammes en produisant des étincelles pendant 60
secondes. Si les flammes ne s'allument toujours pas, le système se met en mode verrouillage.
Il faut alors le réinitialiser en suivant les étapes ci-dessous (pour le déverrouiller) :
a) Attendre 5 minutes et éteindre l'appareil en appuyant sur la touche ON/OFF de la télécom-
mande.
b) Attendre 2 secondes et appuyer encore une fois sur la touche ON/OFF.
c) L'appareil répète l'étape 2.
TO TURN OFF GAS APPLIANCE
1)
Press the ON/OFF button on the remote.
2)
If service is to be performed–you must disconnect power and shut off gas to the unit.
1)
Appuyer sur la touche ON/OFF de la télécommande.
2)
En cas d'entretien, débrancher l'alimentation électrique et couper le gaz.
DO NOT REMOVE THIS INSTRUCTION PLATE
Part #: 919-876a - Side B
Colours: Black on white, except for parts indicated as being Red.
Punch out .25" hole top right corner where indicated.
LIGHTING INSTRUCTIONS
owner's information
RC500E |
11