Residential and Manufactured Homes / Mobile Homes
Minimum Horizontal Termination Installations
Planning Your Venting Installation
See the "Exterior Vent Terminal Locations"
section for requirements.
When planning your installation, it will be necessary
to select the proper length of vent pipe for your
particular requirements. Determine the minimum
clearance to combustibles from the rear of the unit
to the wall. It is also important to note the wall thick-
ness. Before cutting the vent hole through the wall
ensure that ALL vent and termination clearances
(Refer to the "Exterior Vent Terminal Locations"
section) will be met.
*If this is an outside corner, the minimum distance
between the vent and the outside corner is 6"
(15cm). See "F" on the diagram in the "Exterior
Vent Terminal Locations" section.
AstroCap
*
#946-523/P
Max. 12"
(305mm)
**Min.
6-1/2"
(165mm)
A
Min. 2" (51mm)
If outside corner see note * above.
Max. 12" (305mm)
Min. 2"
(51mm)
clearance to
rear of stove
NOTE: Ensure compliance with the outside vent
terminal location before cutting hole as both dimen-
sions must be met.
You will require the following components with your new RC500E Direct Vent Freestanding Gas Stove.
Please review your product to make sure you have everything you need. In the event that you are missing
any part, contact your dealer. Decorative brass or chrome trim kits are available from Simpson Dura-Vent
for their wall thimbles, as well as a square wall thimble cover.
Note: These are the minimum pieces required. Other parts may be required for your
Minimum components for a Horizontal Installation:
380-946
1
1
1
1
1
1
AstroCap
Optional Components:
#946-523/P
946-206
946-506/P
particular installation.
Pipe Length (max. 12")
Kit #380-946
Horizontal Termination Kit which includes:
6-5/8" Dia. x 12" Black Pipe
4" Dia. x 12"
Aluminum Vent
946-202
Wall Penetration Heat Shield (Wall Thimble) (2 pcs)
946-523/P
AstroCap
640-545/P
Decorative Wall Trim (Black)
948-128
Tube Mill-Pac Screws
Vinyl Siding Standoff (AstroCap)
Vent Guard (AstroCap)
Vinyl Siding
Standoff (Optional)
Part #946-206
Wall Thimble
Decorative
(required for
Wall Trim
combustible walls)
Part #640-545/P
Part #946-202
installation
AstroCap
Termination Cap
(Part #946-523/P)
RC500E |