Outside Side Glass Replacement; Accent Light Bulb Replacement; Fan Maintenance / Replacement - Regency Contura RC500E Owners & Installation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

owner's information
outside side glass
tooltip
replacement
1. Turn off stove and allow it to return to room
temperature.
2. Lift off cast top and place on a soft surface.
Remove side safety screen.
tooltip
3. Remove 1 screw in location shown to release
side panel.
4. Slide side panel straight up to remove.
5. Bend out 4 tabs 90° until straight to release glass.
6. Replace glass and secure by folding 4 tabs back
in towards glass.
7. Reinstall panel with new glass.
Note: line up panel with pin at base of unit - secure
panel with one screw.
8. Reverse Step 2-1.
| RC500E
20
accent light bulb
replacement
1. Turn off stove and allow it to return to room
temperature.
2. Lift off cast top and place on a soft surface.
3. Remove 4 screws from each light assembly
housing in locations shown below.
Top of Unit
4. Lift housing off unit to replace bulb.
Note: Do not touch bulb with bare hands, use gloves
or a tissue to handle bulb.
5. Reinstall 4 screws to secure each housing.
6. Reinstall cast top.

fan maintenance / replacement

If your fan requires maintenance or replacement,
access to the fan is through the rear access panel
on the back of the unit. NOTE: the unit MUST
NOT be operated without the fan access panel
securely in place and correctly sealed.
IMPORTANT: These fans collect a lot of dust from
within your home. Ensure you maintain these
fan motors on a regular basis by vacuuming
out the fan squirrel cages, around the motor,
and around the grills on the back of the stove.
WARNING:
Electrical Grounding Instructions
This appliance is equipped with a
three pronged (grounding) plug for
your protection against shock haz-
ard and should be plugged directly
into a properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.
IMPORTANT
Disconnect power supply
before servicing
1. Shut unit off and allow to return to room tempera-
ture, shut off gas and electrical supply.
2. Open lower door and remove lower access panel
(see detailed instructions in this manual).
3. Disconnect gas line to allow removal of fan.
4. Remove 2 screws to release fan and manoeuver
fan to the right and then out of unit.
5. Replace fan (if necessary) and reverse steps 4-1.