installation
You will require the following components with
your new Direct Vent Freestanding Gas Stove.
Please review your product to make sure you
have everything you need. In the event that
you are missing any part, contact your dealer.
Note: These are the minimum pieces
required. Other parts may be
required for your particular in-
stallation. See above for a list of
vent parts.
If installing termination on a siding covered wall,
a vinyl siding standoff or furring strips can be
used in order to ensure that the termination is
not recessed into siding.
The vinyl siding standoff is required for walls
with vinyl siding.
Minimum components for a Dura-Vent
Horizontal Installation:
A) Dura-Vent Horizontal Termination Kit
B) Wall Thimble (required for combustible walls)
Minimum components for a Dura-Vent
Vertical Termination:
D) Dura-Vent Vertical Termination Kit. See
above for pipe lengths.

Horizontal terminations

1. Set the unit in its desired location. Check to
determine if wall studs are in the way when
the venting system is attached. If this is the
case, you may want to adjust the location
of the unit.
Vertical rise with a minimum of 90
degree elbow installed.
center
of hole
C L
Diagram 1
Rear vented
center
of hole
C L
Diagram 1a
| RC500E
40
2. Assemble the desired combination of pipe
and elbow to the appliance adapter with pipe
seams oriented down. Offset the pipe seams
as double seams in one place will cause the
outer pipe to take an oval shape.
3. With the pipe attached to the stove, slide the
stove into its correct location, and mark the
wall for a 9-1/2" (inside dimensions) round
hole. The center of the round hole should line
up with the centerline of the horizontal pipe,
as shown in diagram 1. Cut and frame the
9-1/2 round hole in the exterior wall where
the vent will be terminated. If the wall being
penetrated is constructed of non-combustible
material, i.e. masonry block or concrete, a
7" diameter hole is acceptable.
a) The horizontal run of vent should have a
1/4 inch rise for every 1 foot of run towards
the termination. Never allow the vent to run
downward. This could cause high tempera-
tures and may present the possibility of a
fire.
b) The location of the horizontal vent termina-
tion on an exterior wall must meet all local
and national building codes, and must not be
blocked or obstructed. Refer to the "Exterior
Vent Terminal Locations" section.
c) Snorkel Terminations:
For installations requiring a vertical rise
on the exterior of the building, 14-inch and
36-inch tall Snorkel Terminations as shown
in Diagram 2 are available, as well as the
standard Riser Vent. Follow the same in-
stallation procedures as used for standard
Horizontal Termination. NEVER install the
snorkel upside down.
*Diagram 2a: As specified in CGA B149 Instal-
lation Code. Local codes or regulations may
require different clearances.
Centerline
Centerline
Diagram 2a
Diagram 2b
NOTE:
grade installations, follow national or
local code requirements.
If the Snorkel Termination must be installed
below grade, i.e. basement application,
proper drainage must be provided to prevent
water from entering the Snorkel Termination.
Refer to Installation instructions for details..
Do not attempt to enclose the Snorkel within
the wall, or any other type of enclosure.
4. Install wall penetration heat shield in the
center of the 9-1/2" round hole and attach
with wood screws. The four wood screws
provided should be replaced with appropri-
ate fasteners for stucco, brick, concrete, or
other types of sidings. Diagram 3.
5. If installing termination on a siding covered
wall, a vinyl siding standoff or furring strips
must be used to ensure that the termination
is not recessed into the siding. Diagram 3.
6. Take the Riser Vent terminal and separate
the Backing Plate from the Riser Vent Front
by removing 8 screws as shown in Diagram
4.
Snorkel
Min. 12"*
(305mm)
Diagram 3
Riser Vent
Termination
Min. 6-1/4"*
(159mm)
For Snorkel terminations in ABOVE
Below Grade Snorkel Installation