Outside Side Glass Replacement; Accent Light Bulb Replacement; Fan Maintenance / Replacement - Regency Contura RC500EX Owners & Installation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

Outside Side Glass
t t o o o o l l t t i i p p
Replacement
1. Turn off stove and allow it to return to room
temperature.
2. Lift off cast top and place on a soft surface.
Remove side safety screen.
3. Remove 1 screw in location shown to release
side panel.
4. Slide side panel straight up to remove.
5. Bend out 4 tabs 90° until straight to release glass.
6. Replace glass and secure by folding 4 tabs back
in towards glass.
7. Reinstall panel with new glass.
Note: line up panel with pin at base of unit -
secure panel with one screw.
8. Reverse Step 2-1.
Accent Light Bulb
Replacement
1. Turn off stove and allow it to return to room
temperature.
2. Lift off cast top and place on a soft surface.
3. Remove 4 screws from each light assembly
housing in locations shown below.
Top of Unit
4. Lift housing off unit to replace bulb.
Note: Do not touch bulb with bare hands, use gloves
or a tissue to handle bulb.
5. Reinstall 4 screws to secure each housing.
6. Reinstall cast top.
owner's information
Fan Maintenance /
Replacement
If your fan requires maintenance or replacement,
access to the fan is through the unit. NOTE: the
unit MUST NOT be operated without the fan
access panel securely in place and correctly
sealed.
IMPORTANT: These fans collect a lot of dust
from within your home. Ensure you maintain
these fan motors on a regular basis by vacu-
uming out the fan squirrel cages, around the
motor, and around the grills on the back of
the stove.
WARNING:
Electrical Grounding Instructions
This appliance is equipped with a
three pronged (grounding) plug for
your protection against shock haz-
ard and should be plugged directly
into a properly grounded three-
prong receptacle. Do not cut or
remove the grounding prong from
this plug.
IMPORTANT
Disconnect power supply
before servicing
1. Shut unit off and allow to return to room tem-
perature, shut off gas and electrical supply.
2. Open lower door and remove lower access panel
(see detailed instructions in this manual).
3. Remove 2 screws to release fan and manoeuver
fan to the right and then out of unit.
4. Replace fan (if necessary) and reverse steps.
RC500EX |
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Contura rc500ex-ngContura rc500ex-lp

Table of Contents