Canon MF8580Cdw Service Manual page 390

Mf8500/mf8200 series
Hide thumbs Also See for MF8580Cdw:
Table of Contents

Advertisement

■ AUTO RX
● Numeric value parameter
Parameter No.
Function
01;
CI ON time
02;
CI LONG ON time
03;
CI OFF time
04;
CI LONG OFF time
05;
CI MAX OFF time
06;
CI WAIT time
07;
CI frequency
08;
CI frequency lower limit
09;
CI frequency upper limit
■ CNG DETECT
● Numeric value parameter
Parameter No.
Description
01;
At F/T switching
CNG mIN ON time
02;
CNG mAX ON time
03;
Tolerable time of
instantaneous
interruption
04;
CNG OFF time
05;
Number of detection
06;
Hit ratio
07;
At direct connecting to
CNG MIN ON time
answering phone
08;
CNG MAX ON time
09;
Tolerable time of
instantaneous
interruption
10;
11;
Number of detection
12;
Hit ratio
8
Service Mode > FAX > Setting of NCU Parameters > DAM
Setting range
M82 M85
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (cycle)
0 to 9999 (Hz)
0 to 9999 (Hz)
T-8-40
Setting range
M82 M85
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
-
-
0 to 9999 (x 10 msec)
-
-
0 to 9999 (times)
-
-
0 to 9999 (%)
-
-
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
-
-
-
-
0 to 9999 (times)
0 to 9999 (%)
T-8-41
8
Service Mode > FAX > Setting of NCU Parameters > DAM
■ RKEY
● Numeric value parameter
Parameter No.
Function
01;
Connection time of flash
02;
Connection time of grounding wire 0 to 9999 (x 10 msec)
03;
-
■ PBX DIAL TONE 1
Not in use
■ PBX BUSY TONE
Not in use
■ FTSW OGM
Not in use
■ DAM
Not in use
8-42
Setting range
M82 M85
0 to 9999 (x 10 msec)
-
-
-
T-8-42
8-42