I/O

■ R-CON
COPIER>IO>R-CON
Address
BIT
Description
P001
0
Display sensor status
(Document end sensor)
1
Display sensor status
(Document sensor)
2
Display sensor status (HPS)
P002
-
No sensor allocated; 0 is
always shown
8
Service Mode > COPIER > ADJUST > ADJ-XY
M82 M85
Remarks
While the screen is open, the values
are updated periodically (with an
interval of 1 second).
While the screen is open, the values
are updated periodically (with an
interval of 1 second).
8
Service Mode > COPIER > ADJUST > ADJ-XY

ADJUST

■ ADJ-XY
COPIER > ADJUST > ADJ-XY
ADJ-X
Details
T-8-5
Use case
Adj/set/operate method Enter the setting value (switch negative/positive by -/+
Caution
Display/adj/set range
Unit
Default value
ADJ-Y
Details
Use case
Adj/set/operate method Enter the setting value (switch negative/positive by -/+
Caution
Display/adj/set range
Unit
Default value
Adj of img pstn in book mode: vert scan
To adjust the image reading start position (image leading
edge position) in the vertical scanning direction at
copyboard reading.
When replacing the Engine Controller PCB/clearing the
RAM data, enter the value of service label.
When the non-image width is larger than the standard
value, set the smaller value.
When out of original area is copied, set the larger value.
As the value is incremented by 1, the image position
moves to the trailing edge side by 0.1 mm.
• When replacing the Reader Unit
• When replacing the CIS Unit
key) and press OK key.
After the setting value is changed, write the changed
value in the service label.
-30 to 30
0.1 mm
0
Adj of img pstn in book mode: horz scan
To adjust the image reading start position in the horizontal
scanning direction at copyboard reading.
When replacing the Engine Controller PCB/clearing the
RAM data, enter the value of service label.
When the non-image width is larger than the standard
value, set the smaller value.
When out of original area is copied, set the larger value.
As the value is incremented by 1, the image position
moves to the rear side by 0.1 mm.
• When replacing the Reader Unit
• When replacing the CIS Unit
key) and press OK key.
After the setting value is changed, write the changed
value in the service label.
-10 to 10
0.1 mm
0
8-7