4
Disassembly/Assembly > Controller System > Removing the Main Controller PCB > After replacing main controller PCB
CAUTION:
Be sure to perform the following when connecting the Flat Cable [1] to the connector
with a lock [2].
Be sure to insert the Flat Cable [1] into the connector with a lock [2], and after checking
that both sides (edges) [A] of the Flat Cable [1] are fitted in the 2 grooves [B] of the
connector with a lock [2], lock the Flat Cable Connector Lock [3].
[1]
[A]
[B]
[2]
[3]
[1]
[A]
[B]
[2]
[3]
4
Disassembly/Assembly > Controller System > Removing the Main Controller PCB > After replacing main controller PCB
[1]
[A]
[B]
[2]
[1]
[A]
[B]
[2]
F-4-116
■ After replacing main controller PCB
1. Setting of destination/paper size group
1) COPIER > OPTION > BODY > LOCALE (to set destination groups)
[Settings]
1: Japan, 2: North America, 3: Korea, 4: China, 5: Taiwan, 6: Europe, 7: Asia,
8: Oceania
2) COPIER > OPTION > BODY > SIZE-LC (to set paper size groups)
[Settings]
1: AB series, 2: Inch series, 3: A series, 4: AB/Inch series
2. Clearing Setting/Registration data
1) COPIER > FUNCTION > CLEAR > ALL (to clear all data)
Once executed, the following data are cleared according to the values of LOCALE and
SIZE-LC set in step 1.
• Setting / Registration data (the default value for each destination is set).
• Service mode data (the default value for each destination is set).
• Job IDs
• Log data
• Dates
2) COPIER > FUNCTION > CLEAR > R-CON (to clear default setting values for the
reader/DF)
3. Adjustment, input of default setting values
1) Close the ADF.
2) COPIER> FUNCTION > CCD > CL-AGC, BW-AGC (to adjust white levels)
The white level is adjusted.
3) Enter default setting values indicated on the service label in the corresponding service
mode items.
4) COPIER> FUNCTION > VIFFNC > STOR-DCN (to back up DC controller setting
values)
Purpose: to be prepared for replacing DC controller PCBs
5) Turn off and on the power.
6) Start in the initial installation mode. Follow instructions shown on the screen for setup.
(setting of date/time, auto-gradation correction)
4-59