Event list

The following table lists events related to the CPU module.
Event
Event
Event
code
type
category
00100
System
Info
00110
00120
00130
00140
00400
00401
00410
00411
00420
00430
00440
00450
00460
00700
APPX
790
Appendix 2 Event List
Detected event
Description
■CPU module
Link-up
The CPU module has entered into the
link-up state as a result of an operation
such as connecting a network cable
between the CPU module and an external
device.
■Redundant function module
The redundant function module has
entered into the communication enable
state.
*This event code does not indicate the
start of tracking communication.
Communication
Data communications with an external
start/end (TCP)
device through TCP connection started.
Or, data communications with an external
device through TCP connection ended.
FTP connection
FTP connection with an external device
start/end
started. Or, FTP connection with an
external device ended.
Receive frame error
A receive frame error was detected.
SNTP server time
Time setting by the time synchronization
synchronization
function failed because there was no
failure
response from the SNTP server.
Power-on/reset
The CPU module has been power-on or
reset.
Initial processing
The CPU module has been powered off
cancelled
or reset during initial processing.
Boot operation
Boot operation was performed.
SD memory card
SD memory card diagnostics have
diagnostics
completed.
completed
Event history file
An event history file was generated.
generation
SFC program
An SFC program could not be resumed,
continue start not
and an initial start was performed.
possible
Safety operation
The safety operation mode was
mode undefined
undefined, and the system started in
TEST MODE.
Daylight saving time
Daylight saving time started. Or, daylight
start/end
saving time ended.
Label initialization
After the data is rebuild (reassigned),
labels were initialized when the system
was powered off and on or the operating
status of the CPU module was changed
from STOP to RUN. (Initial values were
set or values were cleared to zero.)
Tracking
Tracking communication started.
communication start
Auto system A/B
The system A/B setting was automatically
setting
set by the redundant system. (The setting
was overwritten.)
Detailed information
Detailed
Detailed
information 1
information 2
Operation
Communication
source
speed and
information
communication
mode
Communication
status
Start-up
*2
information
Information on
the initial
processing
cancellation
Event history
file information
Daylight saving
time status
System A/B
setting
information
Detailed
information 3