Online Module Change Function - Mitsubishi Electric MELSEC iQ-R-R00CPU User Manual

Melsec iq-r series cpu module application user's manual
Table of Contents

Advertisement

Online module change function

The following is the list of special relay areas relating to the online module change function.
No.
Name
SM1600
Module selection request
flag
SM1601
Module selection
completion flag
SM1602
Module removal request
flag
SM1603
Module removal ready flag
SM1604
Module removal completion
flag
SM1605
Module mounting
completion flag
SM1606
Module recognition request
flag
SM1607
Module recognition
completion flag
SM1608
Module control resumption
request flag
SM1609
Online module change
completion flag
SM1615
Module selection
cancellation request flag
Data stored
Details
OffOn:Requested
This relay is turned on to select an online
change target module. When changing a
module directly, the system turns on this
relay upon removal of the target module.
The relay can be turned on only when the
value set in SD1617 is 0 (Normal operation).
The relay turns off upon completion of the
online module change processing. If the
selection cancel is requested, the relay
turns off after the selection is cancelled.
Off: No module selected
This relay turns on when an online change
On: Selected
target module has been selected. The relay
turns off upon completion of the online
module change processing.
OffOn:Requested
This relay is turned on to request a removal
of the selected module. When changing a
module directly, the system turns on this
relay upon removal of the target module.
The relay can be turned on only when the
value set in SD1617 is 2 (Module selected).
The relay turns off upon completion of the
online module change processing.
Off: Not prepared
This relay turns on when the selected
On: Ready
module is ready to be removed. The relay
turns off upon completion of the online
module change processing.
Off: Not completed
This relay turns on when the selected
On: Completed
module has been removed. The relay turns
off upon completion of the online module
change processing.
Off: Not completed
This relay turns on when a new module has
On: Completed
been mounted. The relay turns off upon
completion of the online module change
processing.
OffOn:Requested
This relay is turned on to request
recognition of the newly-mounted module.
When changing a module directly, the
system turns on this relay upon mounting of
the module. The relay can be turned on only
when the value set in SD1617 is 6 (Module
mounted). The relay turns off upon
completion of the online module change
processing.
Off: Not recognized
This relay turns on when the newly-mounted
On: Recognized
module is recognized by the system. The
relay turns off upon completion of the online
module change processing.
OffOn:Requested
This relay turns on to start control of the
replaced module. When changing a module
directly, the system turns on this relay upon
recognition of the module. The relay can be
turned on only when the value set in
SD1617 is 8 (Module recognized). The relay
turns off upon completion of the online
module change processing.
Off: Not completed
The relay turns on upon completion of the
On: Completed
online module change processing. This
relay turns off in the next scan.
OffOn:Module selection
This relay is turned on to cancel a module
cancellation requested
selection request. The relay can be turned
on only when the value set in SD1617 is 2
(Module selected). The relay turns off after
the selection is cancelled.
Set by (setting timing)
S (Status change)/U
(Request)
S (Status change)
S (Status change)/U
(Request)
S (Status change)
S (Status change)
S (Status change)
S (Status change)/U
(Request)
S (Status change)
S (Status change)/U
(Request)
S (Status change)
S (Status change)/U
(Request)
Appendix 4 List of Special Relay Areas
CPU
RnP
RnPSF
RnP
RnPSF
RnP
RnPSF
RnP
RnPSF
RnP
RnPSF
A
RnP
RnPSF
RnP
RnPSF
RnP
RnPSF
RnP
RnPSF
RnP
RnPSF
RnP
RnPSF
APPX
827

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents