33.4

Safety Data Identify Check

This function checks if the project data created using the engineering tool and the data in the Safety CPU are the same, and
confirms that the program executed in SAFETY MODE is the one written by the user.
This function compares files in the engineering tool with files stored in the Safety CPU, and shows the comparison result.
[Online]  [Safety PLC Operation]  [Safety Data Identify Check]
For details, refer to the following.
 GX Works3 Operating Manual
33.5

Safety Communication Function

This function communicates data between the Safety CPU and modules supporting safety functions using safety protocols.
The Safety CPU performs safety communications between safety stations using the following network.
• CC-Link IE Field Network (safety communication function)
For details on the function and settings required for safety communications, refer to the following.
 MELSEC iQ-R CC-Link IE Field Network User's Manual (Application)