Tachometer Will Not Shift to Digital Display.
METER: With the couplers connected,
Meter Does
short Lg/Y terminal of meter white 20P
Not Shift
coupler to GlSI terminal of meter white 13P
coupler Meter should shift to digital
display.
Meter
Shifts
ETC UNIT/WIRING: Short LgiY terminal of
Meter Does
ET.C 17P coupler to the 13P G/SI
Not Shift
terminal. Meter is normal if it shifts to
digital display
Meter
Shifts
Check for poor contacl at meter
coupler. If It IS OK. meter is taully.
Open or shorl circuit in harness.
Poor contact at left fairing coupler.
Check for poor contact at ETC unit
coupler. If coupler is OK, ETC unit
printed circuit board is faulty.
Water Temperature/Fuel Gauge Will Not Shift to 011 Temperature/Pressure Gauge.
METER: Short LbiW terminal of meter
Display Does
white 20P coupler to G/BI terminal of
Not Shift
meter white
1
3P coupler. Meter is
normal if display shifts.
Display
~
Shifts
ETC UNIT/WIRING: Short Lb/W terminal of
Display Does
Not Shift
ETC unit to ETC white 1 7P coupler G/SI
terminal. Display should shift.
Display
Shifts
• Check for poor contact al meter
coupler. If it is OK. meter is faulty.
• Open or short circuit in wire harness.
• Poor contact at left fairing coupler.
• Check tor poor contact at ETC unit
coupler. If it is OK. ETC unit printed
circuit board IS faulty.