Non-Contact Door Switch Controller - Omron G9SX User Manual

G9sx series
Hide thumbs Also See for G9SX:
Table of Contents

Advertisement

1-2 Non-contact Door Switch Controller

Power input
Item
Model
Rated supply voltage
Operating voltage range
Rated power consumption (See note.) 3 W max.
Note: Power consumption of loads not included.
Inputs
Item
Model
Safety input (See note 1.)
Feedback/reset input
Note: 1. Only applies to the G9SX-NSA222-T03-@. Refers to input other than that from the Non-contact Door Switch.
2. Provide a current equal to or higher than that of the minimum applicable load of the connected input control device.
Outputs
Item
Model
Instantaneous safety output
(See note 1.)
OFF-delayed safety output
(See note 1.)
Auxiliary output
Note: 1. While safety outputs are in the ON state, the following signal sequence is output continuously for diagnosis.
When using the safety outputs as input signals to control devices (i.e. Programmable Controllers), consider the OFF pulse shown below.
ON
OFF
360 µs max.
2. The following derating is required when Units are mounted side-by-side.
G9SX-NS202-@/G9SX-NSA222-T03-@: 0.4 A DC max. load current
3. Apply the following rated load conditions for inductive loads.
IEC/EN 60947-5-1 DC13: 0.8 A
UL508 Pilot Duty: 0.5 A
G9SX-NS202-@
24 VDC
−15% to 10% of rated supply voltage
Operating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8kΩ (See note 2.)
P channel MOS FET transistor output
Load current: 0.8 A DC max. (See note 2 and 3.)
PNP transistor output
Load current: 100 mA max.
Approx.100 ms
4 W max.
G9SX-NS202-@/G9SX-NSA222-T03-@
G9SX-NS202-@/G9SX-NSA222-T03-@
1. Ratings
G9SX-NSA222-T03-@
G9SX
USER'S GUIDE
73

Advertisement

Table of Contents
loading

This manual is also suitable for:

G9sx-gsG9sx-ns

Table of Contents