What can be seen?
A log of the last 5 failures with the run time when the failure happened is documented in the
Projector Diagnostics.
How to display the Projector Diagnostics?
1. Push the cursor key
2. Press ENTER to display the projector diagnostic menu (menu 2). The last failure will be displayed.
3. Use the cursor keys to scroll through the failure log.
4. Press ENTER to switch to the voltage diagnostics (menu 3).
5. Press EXIT to return to the projector diagnostics menu.
SERVICE MODE
PROJECTOR SET-UP
MEMORY MANAGEMENT
COMMON SETTINGS
I2C DIAGNOSTICS
VOLTAGE DIAGNOSTICS
PROJECTOR DIAGNOSTICS
Select with
or
then <ENTER>
<EXIT> to return
menu 1
or
to highlight 'Projector diagnostics' (menu 1).
PROJECTOR DIAGNOSTICS
Failure nr : 2
Runtime : 180h 30 min
Projector block nr : 4
Coincidence : ON
Deflection : OFF
SF
: yes
SF vert
: no
SF hor
: no
IBCL fail
: no
Arrow keys to scroll,
<ENTER> to see the voltages,
<EXIT> to return.
menu 2
VOLTAGE DIAGNOSTICS
+17V
-17V
+9V
+12V
-12V
+30V
-40V
EHT fail : no
+110V
HD EHT : no
+210V
Fan Fail : yes
HTHD
-conv
+conv
foc_lo
foc_hi
menu 3
77
:
16.9 Volt
:
-17.1 Volt
:
+9 Volt
:
+11.9 Volt
:
-11.8 Volt
:
+29.8 Volt
:
-39.8 Volt
:
+110 Volt
:
+209 Volt
:
:
:
:
:
<EXIT> to return.