D Beam Setting Parameters - Roland SP-606 Owner's Manual

Roland sampling workstation owner's manual sp-606
Hide thumbs Also See for SP-606:
Table of Contents

Advertisement

D Beam Setting Parameters

TRIGGER
As an alternative to striking the pad itself, you can use the D Beam controller to play a specified pad.
Parameter
Pad Number
Pad Velocity
Trig Mode
SYNTH
This lets you use the D Beam to control the pitch of a built-in monophonic synthesizer.
Parameter
Send Select
Pitch Low
Pitch High
Scale
Level
Osc Wave
PWM Depth
PWM Duty
Value
Explanation
1–16
Specifies the pad number that will be played by the D Beam controller.
1–127
Specifies the loudness of the pad sound played by the D Beam controller.
MOMENTARY,
Specifies what will happen when you place your hand above the D Beam.
LATCH
MOMENTARY: The pad sound will be on only while your hand stays above the
LATCH:
Value
Explanation
DRY, MFX
Specifies whether an effect will be applied.
DRY: The synth sound will not be sent to the effect.
MFX: The synth sound will be sent to the effect.
0–127
Specifies the lower pitch limit for the D Beam controller.
0–127
Specifies the upper pitch limit for the D Beam controller.
CHROMATIC,
Specifies the scale that will be used. Moving your hand closer to the D Beam
TCHEREPINS,
controller will produce higher pitches. Choose one of the following 21 scales.
SPANISH,
CHROMATIC:
BLUES MIXO,
TCHEREPINS:
COMB DIM,
MAJOR,
SPANISH:
MINOR,
BLUES MIXO:
HARMONIC MAJ,
COMB DIM:
HARMONIC MIN,
MAJOR:
DBL HARMONIC,
MELO MIN,
MINOR:
GYPSY,
HARMONIC MAJ: Harmonic Major Scale
DOMINANT,
HARMONIC MIN: Harmonic Minor Scale
HEX,
DBL HARMONIC: Double Harmonic Scale
HEX BLUE,
AUGMENT,
MELO MIN:
RYUKYU,
GYPSY:
INSEN DEC,
DOMINANT:
INSEN ASC,
HEX:
PENTA,
PENTA MIN
HEX BLUE:
AUGMENT:
RYUKYU:
INSEN DEC:
INSEN ASC:
PENTA:
PENTA MIN:
0–127
Specifies the volume of the synth sound.
SAW, TRI, PLS,
Selects the waveform of the oscillator that generates the sound.
NOISE
SAW ( sawtooth wave ): A thick sound rich in overtones.
TRI (triangle wave): A mild sound with fewer overtones.
PLS (pulse wave):
NOISE:
0–127
Depth specifies the depth to which the LFO will modulate the pulse width of
the pulse wave. This creates a distinctive cyclic tonal change. Higher settings
produce a deeper effect.
0–127
Specifies the width of the pulse. Higher settings produce a narrower pulse
width.
D Beam; it will turn off when you take your hand away.
The pad sound will alternately turn on/off each time you place
your hand above the D Beam.
Chromatic Scale
Tcherepnin's Scale
Spanish Scale
Blues Mixolydian Scale
Combination of Diminished Scale
Diatonic Major Scale
Natural Minor Scale
Melodic Minor Scale
Gypsy Scale
Dominant Scale
Whole Tone Scale
Hexatonic Blue Scale
Augmented Scale
Ryukyu Scale
In Sen Scale, Decending
In Sen Scale, Ascending
Major Pentatonic Scale
Minor Pentatonic Scale
The sound will be affected by the following two settings
("PWM Depth" and "PWM Duty").
Noise.
Chapter 9. Using the D Beam
73

Advertisement

Table of Contents
loading

Table of Contents