Changing Numeral and Character String Display
506
Touch switch No. 10
LINE
TARGET
ACHIEVED
Numeral display
(numeral memory table No. 51 is designated in indirect specification)
Touch switch No. 11
S PC program
Make a PC ladder program as shown below.
The program must also be made so that the value of "ACHIEVED" is stored to
D0010 and the value of "TARGET" is stored to D0011.
00100
00101
S Program operation
(1) When "TARGET" (touch switch No. 10) is pressed, the contents of nu-
meral memory table No. 101 (the value of the target production) is dis-
played.
(2) When "ACHIEVED" (touch switch No. 11) is pressed, the contents of
numeral memory table No. 100 (the value of the production actually
achieved) is displayed.
In this example, the contents of numeral memory table No. 51, which is refer-
enced in indirect specification is not checked. If the program is actually tested,
the contents of numeral memory table No. 51 must not be outside the range of
0100 to 0101.
By using the lamp bit of the touch switch, it is possible to identify which of the
numeral memory tables is used for display. For details, refer to 7-7 "Touch
Switches" (page 334).
320
units
@INC (38)
Numeral memory table No. used
DM0000
in indirect specification
@DEC (39)
Numeral memory table No. used
DM0000
in indirect specification
Section 8-5
(1)
(2)