Replacing the Fusing Unit

R CAUTION:
• The Fusing Unit becomes very
hot. When installing the new
Fusing Unit, turn off the printer
and wait about an hour. After
that, install the new Fusing Unit.
Not waiting for the unit to cool
down can result in a burn.
If "Replace Fusing Unit (Type C)" ap-
pears on the panel display, replace
the Fusing Unit.
Replace Fusing
Unit (Type C)
A A A A
Turn off the power switch and
unplug the power cable.
Important
❒ Be sure to wait about an hour to
prevent a burn.
B B B B
If the 2 Tray Finisher is installed,
detach it from the printer.
Reference
See p.1 "Detaching the SR770 (2
Tray Finisher)"
C C C C
If the Duplex Unit is installed,
open the Duplex Reversal Unit.
Reference
See p.2 "Opening and Closing
the Duplex Reversal Unit"
Replacing the Fusing Unit
D D D D
If the External Tray is attached to
the printer, raise it in the direc-
tion of the arrow (A A A A ), and remove
it (B B B B ).
E E E E
Pull out the left cover of the print-
er.
F F F F
Open the upper left cover.
Important
❒ Do not touch any areas other
than the handle.
1
ZDJP038J
ZDJH047J
ZDJH048J
19