321144
10.2.5

Data Download

To retrieve information from the power/control module, one of the following is required:
• A Light Pen (part number 425930) and a Cassiopeia Smart Tool.
• A Light Pen (part number 425930) and a laptop computer with the Fisher & Paykel Smart Tool
diagnostic program loaded.
The steps to download data are:
1a.
Press and hold the MODE button (a short beep will sound).
1b.
Whilst still holding the MODE button, briefly press the TEMPERATURE UP button (a short beep will
sound). This enters diagnostic mode.
Steps 1a and 1b need to be completed within 8 seconds.
2.
Press the TEMPERATURE DOWN button once; this enters data download mode.
A red LED turns on and should be visible on the display.
3.
Place the Light Pen over the top of the red LED until downloading is complete.
4.
Return to normal operation by pressing the MODE button.
If additional help or information is required, please refer to the instructions provided with the Smart Tool, or
ask your Technical Representative.
10.2.6

To Manually Force A Defrost

To manually force a defrost, the steps are:
1a.
Press and hold the MODE button (a short beep will sound).
1b.
Whilst still holding the MODE button, briefly press the TEMPERATURE DOWN button (a long beep
will sound).
Steps 1a and 1b need to be completed within 8 seconds.
1c.
Repeat step 1b and the cabinet will go directly into defrost mode. If the compressor is running, it will
be heard to stop.
NOTE: If the MODE and TEMPERATURE DOWN buttons are pressed only once, the forced defrost will not
occur when the compressor cycles off.
2.
To check if the appliance is in defrost mode, repeat step 1a and 1b.
If a long beep sounds, then the defrost cycle has started.
3.
To exit manual defrost mode, turn the refrigerator off at the power supply, and then while pressing the
MODE button, switch the refrigerator on again at the power supply. If this is not done, the refrigerator
will automatically exit from the manual defrost mode when the defrost is completed.
NOTE: The defrost cycle will not start if the defrost sensor is above +8
(or cut-out) temperature for the defrost.
The defrost cycle follows a predefined sequence. Refer to Section 4.3 for details of the defrost cycle.
10.2.7

Show Room Mode

Enter the diagnostic mode (press MODE and TEMPERATURE UP buttons together) then hold the
TEMPERATURE UP button only for 3 seconds. The Show Room Mode will be entered, which turns off the
normal system control leaving only the PC light operating with no door alarms. There will be a "long" beep
and while the doors are opened the LED display will go through an attention grabbing sequence unless
buttons are pressed, at which time the display will respond as normal. 8 seconds after the last button press
the display sequence will continue. The interior light will switch off after 5 minutes and can only be re-
activated by closing and opening the PC door. The mode may be exited by switching off the appliance at the
power supply.
O
C (46
72
O
F) as this is the termination

Hide quick links: