Problem
Total Compartment
Warm.
FC TOO COLD
Total compartment too
cold.
FC TOO WARM
Bottom warm top frozen.
Total compartment warm.
Possible Causes
* PC duct blocked.
* Evaporator ice up.
* No refrigeration.
* Fans not working.
* Power/control module
failure.
* FC sensor location.
* Faulty sensor.
* PC fan not going.
* Iced up evaporator.
* PC fan not going.
* No refrigeration.
-
Defrost evaporator chassis.
-
Check for door seal.
-
Check defrost element, check continuity.
-
Check door seal / door left open.
-
Does compressor run? If no, check power
supplies. If yes, check refrigeration system.
If running, check for live frost/fully flooded
evaporator. If not, check for leak.
-
Check for fault code (refer to Sections 10.1.1
or 10.2.1).
-
Is there a 12Volt supply, PC light working?
-
If yes, check fan connection(s) at fan end, also
at power/control module end of the harness.
-
If no, check for power/control module failure.
-
Are lamp / interface LED's working?
-
If not, check display module connection.
-
If OK, is compressor running?
-
If not, replace power/control module.
-
Check set temperature.
Sensor
clipped
position?
-
Check calibration of sensor ice point using
interface binary (refer to Sections 10.1.5 or
10.2.3) or refer to thermistor resistance table
(refer to Section 4.22).
-
Check for fault code (refer to Sections 10.1.1
or 10.2.1).
-
Check for mechanical obstruction.
-
Check polarity.
-
Check for broken wires.
-
Replace fan.
-
Check defrost element is working, replace if
faulty.
-
Check doors are sealing or have they been left
open? Adjust and advise customer.
-
FC fan jammed? Clear restriction, replace fan
if necessary.
-
Check defrost sensor position, reposition onto
chassis if not already there.
-
Check for fault code (refer to Sections 10.1.1
or 10.2.1).
-
Check for mechanical obstruction.
-
Check polarity.
-
Check for broken wires.
-
Replace fan.
-
Does compressor run? If no, check power
supplies. If yes, check refrigeration system. If
running, check for live frost / fully flooded
evaporator, if not, check for leak.
124
What To Do
and
located
in
correct