11.1.7
Water Dispenser Pad Replacement
Remove the display module (refer to Section 11.1.6).
To remove the pad, lift the sensor pad upward.
To refit the sensor pad, ensure the retaining clip is
as shown.
11.1.8
Removing Water Tank
Located behind a cover above the PC duct cover.
• Turn the water off at the source.
• Remove all shelves.
• Remove the PC duct cover.
• Remove the PC sensor from the PC duct cover.
• Unclip the water reservoir cover from the cabinet liner.
• The reservoir is removed by sliding a flat bladed plastic putty knife or spatula on top of the tank, and with
a folding motion of the spatula, lever the tank lip from the LH side to the RH side until the clip is lifted from
the liner and the tank is removed.
Diagram A
• Remove the water tubes from the tank.
Diagram A – tank in position.
Diagram B Fit a spatula on the
RH side of the lip and move to the
RH side until unclipped.
Hoses are accessible once the tank is removed.
77
321144
Diagram B