Compressor system fault suspected.
Disconnect power from the
appliance.
Measure compressor winding
resistance between phases
Megger test between compressor
windings and compressor case.
Is insulation
between
windings and
case OK?
Yes
Measure VCC Signal and VCC
Mains harnesses for continuity and
inspect connectors for damage.
Are wires
continuous
and
connectors
undamaged?
Yes
With the refrigerator plugged in and
running, unplug the VCC Signal
harness and measure the frequency
of the signal.
Is signal
between
50Hz and
150Hz?
Yes
Suspect inverter module.
Replace inverter module
with new part and test.
Are winding
resistances
OK?
(Refer Section 1
for compressor
specifications).
Yes
Compressor windings
damaged. Replace
No
compressor with new part.
Harness damaged.
Replace harness with new
No
part.
Suspect power/control
module. Replace
No
power/control module with
new part and test.
47

Equipment Required

• Multimeter with
resistance (Ω) scale
and frequency (Hz)
scale.
• Insulation tester
("megger").
• Spare VCC Inverter.
No
Note: A damaged
compressor could cause
damage to the inverter
module. If the compressor
windings are damaged, the
inverter may need to be
replaced as well.
Note: A damaged harness
could cause damage to the
inverter module. If the
harness wires have shorted
to each other or to the
refrigerator chassis, the
inverter may need to be
replaced as well.
Note: Damage to the
power/control module
which leaves all other
functions of the refrigerator
working correctly but the
compressor not running is
unlikely, but not impossible.
Please double-check that
there is no fault in the
inverter, compressor or
wiring before replacing the
power/control module.