Fisher & Paykel 635 Active Smart Service Manual page 64

Table of Contents

Advertisement

321144
Input/Output Status
Press the UP button once more – Input/Output status.
IO shown indicates the product is in input/output status. The LCDs that are highlighted indicate what
components are on (refer to Section 10.1.6).
NOTE: When the PC door is opened, the backlight will turn off. The LCD for the FC or PC door will come
on when either door is opened.
The IO shown stands for Input/Output, not a temperature.
Diagram D
Input/Output Status
PC2 Sensor Temperature
Press the UP button once more – PC2 sensor. This sensor is attached to the water tank.
O
O
NOTE: 5.0 shown indicates the temperature of the PC2 sensor is 5
C (41
F).
Diagram E
PC Sensor 2
Icemaker Sensor Temperature
Press the UP button once more – Icemaker sensor.
O
O
NOTE: 12.0 min shown indicates the temperature of the Icemaker sensor is -12
C (10.4
F).
Diagram F
Icemaker Sensor
Fault History
Press the UP button once more – Fault History.
H O will be showing.
Diagram G
Fault History
To exit the diagnostic mode, press the MENU button. If not terminated manually, the diagnostic mode will
time out and go back to default display after 5 minutes.
64