Fisher & Paykel 635 Active Smart Service Manual page 58

Table of Contents

Advertisement

321144
Fault Code 8
Reason:
Primary Action:
Secondary Action:
Fault Code 9
Reason:
Primary Action:
Secondary Action:
Fault Code 10
Reason:
Primary Action:
Secondary Action:
Fault Code 11
Reason:
Primary Action:
Secondary Action:
Tertiary Action:
Fault Code 12
Reason:
Primary Action:
Secondary Action:
Tertiary Action:
Fault Code 13
Reason:
Primary Action:
Secondary Action:
Fault Code 14
Reason:
Primary Action:
Secondary Action:
Fault Code 15
Reason:
Primary Action:
Secondary Action:
Fault Code 16
Reason:
Primary Action:
Secondary Action:
Fault Code 17
Reason:
Primary Action:
Secondary Action:
The resistance of the Evaporator sensor is outside the normal range
(<660 Ohms).
Check the sensor connection at the power module.
Replace the sensor.
The
resistance
of
(> 45K Ohms).
Check the sensor connection at the power module.
Replace the sensor.
The
resistance
of
(< 660 Ohms).
Check the sensor connection at the power module.
Replace the sensor.
The current measured for the ambient heater, PC fan and FC fan is lower than
expected.
Check the 6-way fan/LAH RAST connector at the power module.
Re-terminate the 6-way fan/LAH RAST connector.
Replace power/control module.
The current measured for the ambient heater, PC fan and FC fan is higher than
expected.
Check the 6-way fan/LAH RAST connector at the power module.
Re-terminate the 6-way fan/LAH RAST connector.
Replace the power/control module.
The low ambient heater is drawing less current than expected. Either the heater or
wiring is open circuit or the heater is faulty.
Check the wiring and connections at both the heater and the power module.
Check the low ambient heater resistance. If not within limits, replace.
The low ambient heater is drawing more current than expected. Either there is a
short in the heater, or the heater is faulty.
Check the wiring and connections at both the heater and the power module.
Check the low ambient heater resistance. If not within limits, replace.
The PC fan is drawing less current than is expected. Either the wiring is open
circuit or the fan is faulty.
Check the PC fan wiring and connections at both the fan and the power module.
Check the fan. If faulty, replace.
The PC fan is drawing more current than is expected. Either the wiring is shorted
or the fan is faulty.
Check the PC fan wiring and connections at both the fan and the power module.
Check the fan. If faulty, replace.
The FC fan is drawing less current than is expected. Either the wiring is open
circuit or the fan is faulty.
Check the FC fan wiring and connections at both the fan and the power module.
Check the fan. If faulty, replace.