Motorola MCS 2000 User Manual page 138

Radio service software
Hide thumbs Also See for MCS 2000:
Table of Contents

Advertisement

Slow Scroll Rate (ms)
Fast Scroll Rate (ms)
Slow Scroll Count
Save Dim State
Native Language
Alt Display Time (ms)
Temp Msg Display Time (ms)
Emergency Receive
132
Use the UP/DOWN arrow keys to select the Slow Scroll Rate, the rate
at which the display will slow scroll through a list. The radio will first
slow scroll and then fast scroll after the slow scroll count expires. Valid
entries are 250 to 6250 ms in 250-ms increments.
Note: The Slow Scroll Rate should be greater than or equal to
Fast Scroll Rate but less than or equal to 6250 (that is, 250 <= Fast
Scroll Rate <= Slow Scroll Rate <= 6250).
The default is 1000 ms.
Use the UP/DOWN arrow keys to select the Fast Scroll Rate, the rate at
which the display will fast scroll through a list. The radio will first slow
scroll and then fast scroll after the slow scroll count expires. Valid
entries range from 250 to 6250 ms in 250-ms increments.
Note: The Fast Scroll Rate should be greater than or equal to 250
but less than or equal to Slow Scroll Rate (that is, 250 <= Fast
Scroll Rate <= Slow Scroll Rate <= 6250).
The default is 250 ms.
Use the UP/DOWN arrow keys to select the number of menus to be
scrolled before the radio switches to the Fast Scroll Rate. Valid entries
range from 0 (zero) to 255.
The default is 3 menus.
Use the UP/DOWN arrow keys to enable/disable this option. If this
field is enabled, display brightness will to be saved to the EEPROM for
use during power-up initialization.
The default is Disabled.
Use the UP/DOWN arrow keys to select the language for radio display.
Valid entries are English, Spanish, French, German, Italian and
Portuguese.
The default is English.
Use the UP/DOWN arrow keys to select the length of time that an
Alternate message will be displayed. Valid entries range from 250 to
6250 ms in 250-ms increments.
The default is 1 second (1000 ms).
This refers to the length of time that a Temporary message will be
displayed. Valid entries range from 250 to 6250 ms in 250-ms
increments.
The default is 1 second (1000 ms).
This feature is not compatible with Silent Emergency. To enable this feature,
Silent Alarm must be disabled (F4/F3/F2/F7). Use the UP/DOWN arrow
keys to enable/disable the Emergency Receive Display option. If this
feature is enabled, the radio display will alternate between Emergency

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents