3. Registration Roller

1) Remove the right and left covers.
(Page 3-3), (Page 3-5)
2) Remove the frame detection unit and ul-
trasonic drive PCB.
(Page 3-39), (Page 3-20)
3) Remove the control PCB.
(Page 3-13)
Note: Remove this PCB to adjust the tension
of the belt during assembly.
4) Remove the stop ring
magnetic clutch
Figure 3-405
5) Remove the stop rings
Remove the bearings on both sides, es-
cape the arm
registration roller
Figure 3-406
COPYRIGHT © CANON ELECTRONICS INC. 2008
1
and remove the
2
and belt
3
.
1
on both sides.
2
and remove the
3
.
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
Notes on assembling
Hang the arm in procedure 5) on the shaft
and mount the registration roller.
When mounting the magnetic clutch, insert
the rotation stopper.
3-25